TNC-Z0119

Passive bus termination with flat cable connector to make a connection to the AS-i flat cable. Bus termination to improve the signal quality and to extend the AS-i cable network Cable extension up to 200 m

Controller for controlling actuators and for monitoring the damper blade position and duct smoke detectors

  • Controller with TROXNETCOM Basic User Software
  • Easy and safe commissioning without programming
  • Controller with master function for stand-alone operation
  • System monitoring
  • Automatic recognition of components and their status
  • Menu-driven user interface (controller display) for system configuration
  • Peripheral equipment can be tested without additional auxiliary equipment

TNC-Z0119 00134551_0
  • Application

Application

  • Passive bus termination
  • Cable extension up to 200 m without additional repeater
  • Improved signal quality
  • Supply voltage monitoring with 2 LEDs
  • Connection to AS-i cable with flat cable connector
  • Can only be used when actuators have a separate voltage supply

Technical information

  • Function
  • Technology
  • Specification text
  • Order code
AS-i passive bus termination TNC-Z0119 00132721_0

① TNC-70096
② TNC-A1147

DescriptionTNC-Z0119 (TNC-A1147 + TNC-70096)
TypeTNC-A1147
Supply voltage26.5 – 31.6 V DC
Current consumption< 10 mA
Galvanically isolatedYes
Status LEDYellow = AS-i voltage > 18.5 V; green = AS-i voltage > 26 V
Ambient temperature–25 to 70 °C
Protection levelIP 67
MTTF550 years
ConnectionFlat cable insulation displacement connector
NoteNo addressing required
TypeTNC-70096
Max. current load2 A
Ambient temperature–25 to 75 °C
Protection levelIP 67
Casing materialPA
NoteNo addressing required


Standard description (characteristics)

Passive bus termination (TNC-A1147) with flat cable connector (TNC-70096) to make a connection to the AS-i flat cable. Bus termination to improve the signal quality and to extend the AS-i cable network Cable extension up to 200 m.

  • Supply voltage: 26.5 – 31.6 V DC
  • Current consumption: < 10 mA
  • Max. current load: 2 A
  • Ambient temperature: –25 to 70 C°
  • Protection level: IP 67
  • Make: TROX GmbH or equivalent
  • Type: TNC-Z0019

00131013_0
 

 Component
TNC-A1305       Controller with PROFIBUS DP interface; 1 master
TNC-A1306       Controller with PROFIBUS DP interface; 2 masters
TNC-A1353       Controller with Modbus/TCP interface; 1 master
TNC-A1354       Controller with Modbus/TCP interface; 2 masters
TNC-A1375       Gateway with PROFIBUS DP interface; 1 master
TNC-A2225       Repeater
TNC-ZB0252       AS-i safety gateway
TNC-Z0119       Passive bus termination
TNC-A1146       AS-i tuner (diagnosis module)

 

Share page

Recommend this page

Recommend this page by sending a link by mail.

Fields marked with an (*) are required fields.

Share page

Thank you for your recommendation!

Your recommendation has been sent and should arrive shortly.


Contact

We are here for you

Visual contact Visual contact

Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Visual contact Visual contact

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Contact

We are here for you

Visual contact Visual contact

Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Attachment (max. 10MB)

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Visual contact Visual contact

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265